Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Year range
1.
Japanese Journal of Cardiovascular Surgery ; : 140-142, 2001.
Article in Japanese | WPRIM | ID: wpr-366667

ABSTRACT

Primary malignant cardiac tumors are extremely rare. Among these, leiomyosarcoma are particularly exceptional and only about 20 surgically treated cases have been extensively described. We describe a case of right atrial leiomyosarcoma which was accidentally found by computed tomography. The tumor was surgically resected under extracorporeal circulation. Two months later the patient had cerebral hemorrhage due to a brain metastasis, which almost completely disappeared after irradiation. There was no other evidence of recurrence for 12 months after operation.

2.
Japanese Journal of Cardiovascular Surgery ; : 268-270, 1999.
Article in Japanese | WPRIM | ID: wpr-366502

ABSTRACT

We performed surgical correction of a single atrium in a 46-year-old man, who had suffered from congestive heart failure (NYHA II) and pulmonary hypertension (58/23 (36) /mmHg). An intra-atrial shunt (L-R 71%, R-L 14%) due to single atrium and mild mitral and tricuspid regurgitation were detected. The operation consisted of making a new atrial septum with an autologous pericardial patch and direct mitral cleft suture. The post-operative course was uneventful.

3.
Japanese Journal of Cardiovascular Surgery ; : 360-363, 1998.
Article in Japanese | WPRIM | ID: wpr-366436

ABSTRACT

Injuries to the aorta complicating cardiovascular operations can be very challenging. This type of injury is usually related to manipulation of the aorta during surgical exposure or aortic cannulation. From March 1994 to October 1997, five patients with intraoperative injuries to the thoracic aorta occurred. Their ages ranged from 7 to 71 years old (mean, 43.5 years). Two were male and 3 female. Intraoperatively, trouble occurred suddenly due to acute aortic dissection related to aortic traumatic hemorrhagic disruption in three patients, and aortic cannulation in two patients. The confirmation of the diagnosis was prompted clinically, and all patients immediately underwent further surgical intervention. In terms of technique, we used a cardiopulmonary bypass (mean cardiopulmonary bypass time 239min, range 196 to 367min), and hypothermic circulatory arrest (mean arrest time 34min, range 20 to 44min, at deep hypothermia with 21.0°C urinary bladder temperature) during repair. Retrograde cerebral perfusion was utilized in two cases to assure protection for cerebral damage. Fortunately, there was no postoperative neurological complication and no hospital death in any of the cases. When such intraoperative injuries of the aorta once occur repair using aortic clamps often fail or is not feasible, and in such cases hypothermic circulatory arrest combined with retrograde cerebral perfusion should be applied to resolve this type of the serious troubles.

4.
Japanese Journal of Cardiovascular Surgery ; : 400-403, 1997.
Article in Japanese | WPRIM | ID: wpr-366352

ABSTRACT

A 24-year-old woman with patent ductus arteriosus underwent division of the ductus. On the fifth postoperative day (POD 5), MRSA was detected in pus from the wound. On POD 8, an emergency operation was performed for left tension hemothorax due to a ruptured aorta with MRSA infection. The bleeding site in the descending aorta was covered with a viable omental flap under deep hypothermic circulatory arrest. Although MRSA was detected in the pleural effusion and the aortic wall, the patient recovered from pyothorax, and pneumonia caused by <i>Pseudomonas aeruginosas</i> and acute renal failure. On POD 37, a pseudoaneurysm of the descending aorta was found and graft replacement was performed on POD 56 due to enlargement of the aneurysm. However, MRSA was not detected in the left pleural effusion. The postoperative course was uneventful. Omental transfer should be considered for the treatment of severe aortic wall infection, even in the presense of MRSA infection.

5.
Japanese Journal of Cardiovascular Surgery ; : 318-321, 1997.
Article in Japanese | WPRIM | ID: wpr-366333

ABSTRACT

To avoid homologous blood transfusion, the effectiveness of autologous blood predonation was evaluated in patients with elective abdominal aortic aneurysm (AAA) repair. From January 1993 to July 1996, 53 patients underwent Y graft replacement by using autologous rapid transfusion device AT1000<sup>®</sup> (Electromedics. Inc, Englewood, CO). The patients were devided in to 3 groups. Thirty one patients had no blood donation (Group A). Twelve patients had 400ml blood donation with administration of an iron preparation (Group B). Ten patients donated the same amount of blood as those in Group B, with administration of both an iron preparation and recombinant human erythropoietin (rHuEPO) (Group C). There were no significant differences in terms of age, gender, operating time, intraoperative bleeding, and total amount of homologous and autologous blood transfusion in the 3 groups. In Group A, the mean volume of homologous blood transfusion was 250±370ml and in both Groups B and C, no homologous blood was required and 400ml autologous blood was used. Homologous blood transfusion was avoided in 58.9 (18/31) of patients in Group A and all of the patients in Groups B and C. Due to the blood predonation prior to surgery, a hemoglobin level decreased significantly at the time of operation in Group B (without rHuEPO), but in Group C (with rHuEPO) the hemoglobin level was kept constant. During the first postoperative week, the minimum hemoglobin level in Group C was significantly higher than in the other groups. In conclusion, by donating 400ml autologous blood before surgery and using an intraoperative autotransfusion system, homologous blood transfusion could be avoided in elective AAA repair. With rHuEPO, the hemoglobin level could be maintained, despite predonation and intraoperative blood loss.

6.
Japanese Journal of Cardiovascular Surgery ; : 267-273, 1992.
Article in Japanese | WPRIM | ID: wpr-365800

ABSTRACT

Seventy patients with rheumatic valvular disease were evaluated with preoperative CT scanning. The correlation of the obtained CT images to the operative findings were examined. Left atrial thrombi were found in 24 cases at the operation. CT scan had detected thrombi in 19 cases (79.2%) and echocardiography in 15 (62.5%). CT failed to find them in 5 cases in which the left atrial thrombi were less than 3g. Echocardiogram, however, failed to detect thrombi in 9 cases, the largest being 14g. There were 15 cases with left atrial calcification, in which 10 cases had left atrial thrombi. Nine cases out of these 10 cases had rough left atrial surface after thrombectomy. Early postoperative CT of 10 with left atrial calcification showed recurrent left atrial thrombi in 4 (40%) cases. Mitral valve calcification was found in 42 cases during operation. CT scan was able to detect it in 40 (95.2%), while echocardiogram detected in 34 cases (81.0%) (<i>p</i><0.05). All mitral valves with calcification required replacement. Out of 30 cases with non calcified mitral valves, 9 underwent OMC, and the other 21 underwent mitral valve replacement. Aortic valve calcification was found in 9 out of 11 cases with aortic stenosis. All has been diagnosed by CT scan. In conclusion, 1. In detecting the left atrial thrombi, CT scan was superior to echo-cardiography, and provided useful information for planning the operative procedure including atrial approach and valvular manipulation. 2. CT scan could detect calcification of left atrial wall which had high incidence of thrombus formation and rough left atrial surface. 3. CT scan could detect calcification of both mitral and aortic valve, and showed the severity of valvular structural changes.

7.
Japanese Journal of Cardiovascular Surgery ; : 229-232, 1992.
Article in Japanese | WPRIM | ID: wpr-365793

ABSTRACT

Eleven cases underwent tricuspid valve replacement with bioprosthetic heart valve between 1981 and 1990. Mean age was 51±12 years old and mean follow up period was 40±40 months. Mitral valve replacement in ten cases and aortic valve replacement in one underwent simultaneously. Warfarin and dipyridamole were prescribed for post-operative anti-coagulant therapy. Post-operative early death within 30 days was seen in two cases and late death was in two cases. Five years survival rate including early death was 70±14% and nine years survival rate was 54±18%. All seven cases excluding demised cases were III°or IV°in NYHA classification preoperatively but six were I°or II°at postoperative period. Preoperative functional status of all fatal cases were IV°. Cardio-thoracic ratio was 76.2±12.8% pre-operatively, 67.7±9.0 one year after operation, 66.3±7.8% three years after operation and 68.9±9.3 five years after operation. In conclusion post-operative cardiac function ameliorated, but could not return to fairly satisfactory state.

8.
Japanese Journal of Cardiovascular Surgery ; : 191-194, 1992.
Article in Japanese | WPRIM | ID: wpr-365785

ABSTRACT

Fifty-two year-old woman was operated for type A acute dissection of the aorta superimposed on pre-existing post-stenotic dilatation dut to congenital aortic valve stenosis. The left main coronary artery was discontinued by dissection. Aortic valve replacement, replacement of ascending aorta by woven-Dacron graft and saphenous vein graft between the left anterior discending artery and the prosthetic graft. Compression gauze around the site of the anastomoses and the prosthetic graft was useful to control of intractable bleeding. The gauze could be extracted twenty-eight hours after the operation by platelet and plasma transfusion. She was well eleven months after the operation.

SELECTION OF CITATIONS
SEARCH DETAIL